Pressure Control

BOP Equipment – Ram & Annular Blowout Preventers

FracSync supplies ram BOPs and annular BOPs for drilling, workover and well service. Working pressures from 2,000 to 20,000 psi and bore sizes from 7-1/16" to 30", in Shaffer, Cameron and Hydril types, for standard and sour (H2S) service.

  • 2,000 – 20,000 psi
  • 7-1/16" – 30" bore
  • Ram & annular BOPs
  • Ram BOPs to API 16A
  • H2S & CO2 service
Double ram BOP and annular BOP blowout preventers

Ram BOP

Ram BOP Specifications

Ram BOPs seal the well with steel rams that close from both sides. They can seal around the pipe, cut the pipe and seal the well, or close an open hole.

SpecificationRam BOP
Working pressure2,000 – 20,000 psi
Nominal bore7-1/16" – 30"
ConfigurationsSingle ram, double ram, double ram with tandem booster (lower cavity)
Ram typesPipe ram, blind shear ram, variable bore ram
TypesShaffer, Cameron and Hydril type
StandardDesigned and manufactured in accordance with API 16A
Working mediaOil, gas and drilling mud, including H2S and CO2
TemperatureTemp class T75, T20, T0 · metal seal level A – D
Hydraulic controlRated 3,000 psi · recommended operating pressure 1,200 – 1,500 psi
LockHydraulic and manual lock
ConnectionsTop, bottom and side outlets flanged or studded · hydraulic ports 1" NPT
Single ram BOP, double ram BOP and double ram BOP with tandem booster
Single ram BOP · Double ram BOP · Double ram BOP with tandem booster

Rams

Ram Types

Pipe RamSeals around pipe

Closes around the drill pipe or tubing to seal the annular space between the pipe and the casing.

Blind Shear RamCuts & seals

Cuts through the pipe in an emergency and seals the full wellbore.

Variable Bore RamFits a pipe range

Seals on a range of pipe sizes, so fewer ram changes are needed.

Annular BOP

Annular BOP Specifications

Annular BOPs use a ring-shaped rubber packing element – spherical or conical – that closes around pipe of almost any size or shape. They are usually installed on top of the ram BOPs, but can also be used on their own.

SpecificationAnnular BOP
Working pressure2,000 – 20,000 psi
Nominal bore7-1/16" – 30"
TypesShaffer type, Cameron type, Hydril type (screw head and latched head)
Packing elementSpherical or conical
Working mediaOil, gas and drilling mud, including H2S and CO2
TemperatureMetal temp class T75, T20, T0 · non-metal seal level A – D
Hydraulic controlRated 3,000 psi · recommended operating pressure 1,200 – 1,500 psi
ConnectionsUpper: flanged, studded or clamp · Lower: flanged or clamp · hydraulic ports 1" NPT
Also availableDrilling spools, 29-1/2" 500 psi and 30" 1,000 psi diverters
Shaffer, Cameron and Hydril type annular BOPs
Shaffer type · Cameron type · Hydril type (screw head) · Hydril type (latched head)

How It Works

What Is a Blowout Preventer?

A blowout preventer (BOP) is a set of large, high-pressure valves installed on top of the wellhead. If formation pressure enters the well, the BOP closes to seal the wellbore and stop a blowout.

A typical BOP stack combines an annular BOP on top with one or more ram BOPs below. The side outlets connect to the choke and kill manifolds, so the crew can circulate the well and bring pressure back under control.

Comparison

Ram BOP vs Annular BOP

  • Ram BOP – steel rams for a tight seal on a set pipe size, shearing the pipe, or closing an open hole
  • Annular BOP – rubber packing that seals on pipe, tool joints, casing, wireline or an open hole
  • Used together – the annular BOP is usually closed first, the ram BOP gives a long-term seal
  • Both – hydraulically operated from a BOP control unit

Applications

Where Our BOPs Are Used

  • Drilling – well control on land drilling rigs
  • Workover – well intervention and workover rigs
  • Completions – frac and completion operations
  • Well service – snubbing, well washing and special operations
  • Sour wells – H2S and CO2 service

What to Include in Your Quote Request

  1. BOP type – ram or annular (Shaffer, Cameron or Hydril type)
  2. Bore size – e.g. 7-1/16", 11" or 13-5/8"
  3. Working pressure – 2,000 to 20,000 psi
  4. Rams – single or double, pipe, blind shear or variable bore
  5. Connections – flanged, studded or clamp, and side outlets
  6. Service, quantity and delivery location
Request a quote

FAQ

BOP Questions

Types, pressure, sizes and quotes.

01What is a BOP in oil and gas?

A BOP (blowout preventer) is a large valve assembly installed on top of the wellhead to seal the well and control pressure during drilling, workover and completion. It prevents an uncontrolled release of oil, gas or mud – a blowout.

02What is the difference between a ram BOP and an annular BOP?

A ram BOP closes with steel rams that move in from the sides – pipe rams seal around the pipe, blind shear rams cut the pipe and seal the well, and variable bore rams fit a range of pipe sizes. An annular BOP uses a ring-shaped rubber packing element that closes around almost any shape in the hole, or on an open hole. They are usually used together in a BOP stack.

03What pressure and sizes are available?

We supply ram and annular BOPs with working pressures from 2,000 to 20,000 psi and nominal bore sizes from 7-1/16" to 30", with flanged or studded connections.

04What types of rams do you supply?

Pipe rams, blind shear rams and variable bore rams, in single ram, double ram and double ram with tandem booster configurations.

05Are your BOPs suitable for sour service?

Yes. Our BOPs are rated for oil, gas and drilling mud, including H2S and CO2 service, with temperature classes T75, T20 and T0.

06What do I need to send for a BOP quote?

Send the BOP type (ram or annular), bore size, working pressure, ram configuration, top and bottom connections, service conditions and quantity. Our Houston team will reply with pricing and availability.

Related Products

Often Ordered With BOP Equipment

Shaffer, Cameron and Hydril are trademarks of their respective owners and are used here only to describe the type of product.